Technical characteristics:
- Insulation voltage: 660V; 50/60Hz
- Surge voltage wear resistance: 6000V
- Rated current: up to 10А (230V АС)
- Short circuit protection: breaker 10А gG outside of the circuit
- Rated consumed current (for indicators and buttons combined with indicators): <20mA
- Wear resistance (indicators): >2000h
- Mechanical wear resistance (buttons): 1х106 commutation cycles
- Mechanical pressure strength:
= At closing: 20N
= At opening: 8N
- Operating temperature: -20° to 65°С
- Humidity: 35-85%RH
- Connecting wires torgue: 0.15Nm
- Section of the conductor : 1х0.5; 1х0.75; 1х1; 1х1.5; 1х2.5mm2
- Plastic: resistant to UV rays
Mounting: On a DIN rail
Standard: EN60947-1; EN60947-5-1